T405S Indicator Service Manual
83
7.1
SMA Protocol
7.1.6 B-TEK Extended SMA Commands
<LF>XA<CR>
This will initiate an Accumulate command. If the
indicator is in ACCUM or COUNT app it will perform an
Accumulation transaction if all required conditions are
met.
The command will also perform the same function as
pressing the
key on the front panel. Response
will be to any communication ports that are binded to a
Type = Print. The port that initiated the command will
also receive an <LF>xa<CR> response.
<LF>XB<CR>
This will initiate a PRINT command. The command will
also perform the same function as pressing the
key on the front panel.
No response.
<LF>XK<CR>
This will return a list of up to the last twenty keys
pressed. The buffer is cleared after this command.
<LF>xk:Y<CR> where Y is:
T for TARE key
S for SELECT key
Z for ZERO key
P for PRINT key
U for UNITS key
F for F1 key
G for START key
H for STOP key
I for ID key
L for TARGET key
J for SAMPLE key
K for SETUP key
C for CLEAR
R for REPORT key
Q for IN/OUT key
E for FLEET key
.
for Decimal key
# for all numeric keys
AWT Extended SMA command/response protocol allows use of the same Network
Tokens shown in ATTRIBUTE: 3 hex
on page 89
.
The list above includes all the keys for all the various models of Z indicators. If your
model of indicator does not have one of these keys, that key will not be included in the
returned list.
XD, XZ and XS commands, below, only work if the indicator is unsealed.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...