68
T405S Indicator Service Manual
6
ADMIN level menus
If
Type
is set to
Client
Type x
,
Port x
,
Host x
, and
Tmout x
are displayed.
These are explained below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key a port
number from 1 to 65535.
Host x
This is the host IP address of the server. Key
in a value from 0 to 255.
Tmout x
If no messages are received within the timout
period the socket will try to reconnect. Key in a
value in seconds from 0 to 60000. Default is 0.
If
Type
is set to
Server
Type x
and
Port x
are displayed. Allowable values for
each are listed below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key in a port
number from 1 to 65535.
If
Type
is set to
UDP
UDP stands for User Datagram Protocol.
Type x
,
Port x
,
LcPrt x
,
RxAdd x
,
TxAdd x
and
DynTX x
are displayed.
These are explained below.
Port x
This stands for Remote Port. You need to pick
the remote port number to send messages to
and receive messages from. Key a port
number from 1 to 65535.
LcPrt x
This stands for Local Port. This is the local port
that the remote IP will send messages to. Key
in a port number from 1 to 65535.
RxAdd x
This stands for Receive from Address. This is
the IP address to receive messages from. A
specific IP address could be specified, or an
address of 0.0.0.0 could be used to receive
from any remote IP address. Key in a value
from 0 to 255.
TxAdd x
This stands for Send to Address. This is the
default remote IP address to send messages
to. This address may not be used at all if
dynamic address is set to ON. Key in a value
from 0 to 255.
DynTX x
This stands for Dynamic Address. Choices are
Off
or
On
. If
On
the firmware will change the
send to IP address to the address that a
message was last received from, so that a
response is sent to the sender that last sent a
message to the indicator. If set to
Off
then all
messages will be sent to the IP address
specified by the
TxAdd x
setting. Default is
Off
.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...