62
T405S Indicator Service Manual
6
ADMIN level menus
Auto
Choices under this are
on
,
PwruP
and
oFF
. Choose
on
(the
default setting) and the indicator will update anytime it
receives an update via FTP. Choose
PwruP
to have the
indicator auto-update on powerup if an update is available.
Choose
oFF
to turn auto-update off.
6.4.11 Password
PASSWd
Use this to change the password for the
AdMin
,
diAg
and
cALib
menus.
6.4.12 Z-Lock
Z-LocK
This stands for zero lock. Use this to enable and configure the zero lock
feature during an automated weighing process. When enabled, if the scale
does not achieve a stable, gross zero condition some time within X
minutes (the time you configure), then the indicator locks up and displays
a message in three, one second displays:
Z-LocK PrESS ZEro
. The
operator must press
ZERO
to unlock the indicator.
EnAbLE
oFF
or
on
.
oFF
is the default.
timE
Use this to set the time value, in minutes, for this function. 60
minutes is the default
If
Auto
=
oFF
, the only way to update the indicator is to use the
MAnuAL
update and
select
YES
.
Passwd
Admin
Diag
Calib
Key in
new PW
Key in
new PW
Key in
new PW
If the ADMIN password is changed, be sure to keep a record of it available for service
personnel or they may not be able to perform required maintenance when necessary.
Enable
On
Time
Z-Lock
Off
Key in time
in minutes
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...