118
T405S Indicator Service Manual
10
Print formatting
10.4 Other scale tokens
In addition to the above, you can examine the tokens available and do much more with
the data. For example suppose the Customer’s PC can’t cope with decimal point in the
weight value from the scale. We can add optional parameters after the Gross weight
token to remove the decimal point. This print format character sequence would look like
this …
[ = t501
indicates the start of an optional parameter
68 = D
for decimal point parameter
50 = 2
for hide decimal point
] = t502
indicates the end of the optional parameter
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
GROSS
lb
The above token and function will output the text “Gross”
The above token and function will output the Gross weight value.
Characters 5 to 8 will remove the decimal point from the weight transmitted using an attribute
parameter. You may need to refer to the
for more detail on
necessary character values.
Summary of Contents for T405S
Page 1: ...AWT35 501638 Issue AA T405S Weight Indicator Service Manual...
Page 2: ...BTEK_T405S_s_en_501638 book...
Page 8: ...8 T405S Indicator Service Manual...
Page 134: ...134 T405S Indicator Service Manual...
Page 147: ...T405S Indicator Service Manual 147 13 7 Outline dimensions...
Page 150: ...150 T405S Indicator Service Manual...
Page 154: ...154 T405S Indicator Service Manual...
Page 155: ......
Page 156: ...B TEK Scale LLC 1510 Metric Ave SW Canton OH 44706 3088...