IP Office Basic Edition - Quick Mode Installation
Page 63
15-601042 Issue 24i (20 December 2011)
IP Office 8.0
IP500 V2 Installation: IP500 Card Installation
4.4.1 IP500 Daughter Card Preparation
IP500 trunk daughter cards can be fitted to any IP500 base card. For IP500 Combination cards, the trunk daughter card is
pre-installed and cannot be changed.
Warnings
1. Correct anti-static protection steps should be taken while handling
circuit boards.
Parts and Equipment Required
1.
o
IP500 Base Card
2.
o
IP500 Trunk Daughter Card
3.
o
3 Stand Off Pillars
These are supplied with the trunk daughter card.
Tools Required.
1.
o
5mm Flat-blade screwdriver.
2.
o
Anti-static wrist strap and ground point.
Procedure: Installing a Trunk Daughter Card
1. Check that correct cards have been supplied.
2. Ensure that you are wearing an anti-static wrist strap connected
to a suitable ground point.
3. On the base card identify the position of 3 holes for the plastic
pillars for the IP500 card. These are along the same edge as the
card connector.
4. Fit the stand off pillars to the IP500 base card.
5. If there is a clip-on metal shield over the connector block on the
base card, remove it.
6. Using minimal force and checking that the pins are correctly
located, push the IP500 trunk card onto its connector block and
the stand off pillars.
7. Check that the card connector has snapped into position.
8. Using the washers and screws provided, secure the metal stand
off pillars to the base card.
9. A set of labels are supplied with the trunk daughter card. Fit the
appropriate label to the front of the base card.