8.6.3 System Shutdown
IP Office systems running IP Office Release 6 can be shut down in order to perform maintenance. The shut down can be
either indefinite or for a set period of time after which the IP Office will automatically reboot.
During the shut down process, the current configuration in the control unit's RAM memory is copied to the control units
non-volatile memory. For IP500 V2 systems that location is the System SD card.
For control units with memory cards the memory cards can be
shutdown and restarted
separately from the system.
·
!
WARNINGS
·
A shutdown must always be used to switch off the system. Simply removing the power cord or switching off
the power input may cause errors.
·
This is not a polite shutdown, any users calls and services in operation will be stopped. Once shutdown, the
system cannot be used to make or receive any calls until restarted.
·
The shutdown process takes up to a minute to complete. When shutdown, the CPU LED and the IP500 base
card LEDs 1 will flash red rapidly. The memory card LEDs are extinguished (LED 9 also if a trunk daughter card
is fitted to the card). Do not remove power from the system or remove any of the memory cards until the
system is in this state.
·
When shutting down a system with a C110 Unified Communications Module card installed, the shutdown
can take up to 3 minutes while the card safely closes all open files and closes down its operating system.
During this period the card's LED 1 will remain green.
·
To restart a system when shutdown indefinitely, or to restart a system before the timed restart, switch power
to the system off and on again.
System Shutdown Using IP Office Manager
1. Using IP Office Manager, select File | Advanced | System Shutdown.
2. Using the Select IP Office menu, the System Shutdown Mode menu is displayed.
3. Select the type of shutdown required. If Indefinite is used, the system can only be restarted by having its power
switched off and then on again. If a Timed shutdown is selected, the IP Office will reboot after the set time has
elapsed.
System Shutdown Using the System Status Application
1. Start
System Status
and access the IP Office's status output.
2. In the navigation panel select System.
3. At the bottom of the screen select Shutdown System.
4. Select the time duration for the shutdown or indefinite.
System Shutdown Using the IP500 V2 AUX Button
When the AUX button is pressed for more than 5 seconds, the IP500 V2 control unit will shutdown with the restart timer
set to 10 minutes.