DRV-28 inverter
s Basic operartion instructions
-52-
Function
code
Name
Detailed parameter description
Default
value
when current motor is motor 1, only P02.06,
P02.07 and P02.08 will be autotuned; when
current motor is motor 2, only P12.06,
P12.07 and P12.08 will be autotuned.
P00.18
Function parameter
restoration
0: No operation
1: Restore to default value
2: Clear fault history
Note: After the selected function
operations are done, this function code
will be restored to 0 automatically.
Restoration to default value will clear the
user password, this function should be
used with caution.
0
P02.00
Type of motor 1
0: Asynchronous motor
1: Synchronous motor
0
P02.01
Rated power of
asynchronous motor 1
0.1–3000.0kW
Depend
on model
P02.02
Rated frequency of
asynchronous motor 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.03
Rated speed of
asynchronous motor 1
1–36000rpm
Depend
on model
P02.04
Rated voltage of
asynchronous motor 1
0–1200V
Depend
on model
P02.05
Rated current of
asynchronous motor 1
0.8–6000.0A
Depend
on model
P02.15
Rated power of
synchronous motor 1
0.1–3000.0kW
Depend
on model
P02.16
Rated frequency of
synchronous motor 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole pairs of
synchronous motor 1
1–50
2
P02.18
Rated voltage of
synchronous motor 1
0–1200V
Depend
on model
P02.19
Rated current of
synchronous motor 1
0.8–6000.0A
Depend
on model
P05.01–
P05.06
Function of multi-function
digital input terminal
(S1–S4, HDIA, HDIB)
36: Command switches to keypad
37: Command switches to terminal
38: Command switches to communication
/