DRV-28 inverter
s Function parameter list
-152-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
motor 1
P04.44
Frequency
threshold for
switching off IF
mode for
asynchronous
motor 1
When IF control is adopted for asynchronous motor
1, this parameter is used to set the frequency
threshold for switching off the output current
closed-loop control. When the frequency is lower
than the value of this parameter, the current
closed-loop control in the IF control mode is enabled;
and when the frequency is higher than that, the
current closed-loop control in the IF control mode is
disabled.
Setting range: 0.00
–20.00 Hz
10.00Hz
○
P04.45
Enable/disable IF
mode for
asynchronous
motor 2
0: Disabled
1: Enabled
0
◎
P04.46
Current setting in
IF mode for
asynchronous
motor 2
When IF control is adopted for asynchronous motor
2, this parameter is used to set the output current.
The value is a percentage in relative to the rated
current of the motor.
Setting range: 0.0–200.0%
120.0%
○
P04.47
Proportional
coefficient in IF
mode for
asynchronous
motor 2
When IF control is adopted for asynchronous motor
2, this parameter is used to set the proportional
coefficient of the output current closed-loop control.
Setting range: 0
–5000
650
○
P04.48
Integral
coefficient in IF
mode for
asynchronous
motor 2
When IF control is adopted for asynchronous motor
2, this parameter is used to set the inetgral
coefficient of the output current closed-loop control.
Setting range: 0
–5000
350
○
P04.49
Frequency
threshold for
switching off IF
mode for
asynchronous
motor 2
When IF control is adopted for asynchronous motor
2, this parameter is used to set the frequency
threshold for switching off the output current
closed-loop control. When the frequency is lower
than the value of this parameter, the current
closed-loop control in the IF control mode is enabled;
and when the frequency is higher than that, the
current closed-loop control in the IF control mode is
10.00Hz
○