DRV-28 inverter
s Optional peripheral accessories
-325-
D.4.2.1 AC 3PH 400V (-20%)
–440V (+10%)
Inverter model
Recommended
cable size (mm
2
)
Size of connectable cable (mm
2
)
Terminal
screw
specifica
tion
Tighten
ing
torque
(Nm)
RST
UVW
PE
RST
UVW
P1, (+) PB, (+), (-)
PE
AS28DRV41C5
2.5
2.5
2.5–6
2.5–6
2.5–6
2.5–6
M4
1.2–1.5
AS28DRV42C2
2.5
2.5
2.5–6
2.5–6
2.5–6
2.5–6
M4
1.2–1.5
AS28DRV44C0
2.5
2.5
2.5–6
2.5–6
2.5–6
2.5–6
M4
1.2–1.5
AS28DRV45C5
2.5
2.5
2.5–6
2.5–6
2.5–6
2.5–6
M4
1.2–1.5
AS28DRV47C5
4
4
2.5–6
4–6
4–6
2.5–6
M4
1.2–1.5
AS28DRV4011
6
6
4
–10
4
–10
4
–10
4
–10
M5
2.3
AS28DRV4015
6
6
4
–10
4
–10
4
–10
4
–10
M5
2.3
AS28DRV4018
10
10
10
–16
10
–16
10
–16
10
–16
M5
2.3
AS28DRV4022
16
16
10
–16
10
–16
10
–16
10
–16
M5
2.3
AS28DRV4030
25
16
25
–50
25
–50
25
–50
16
–25
M6
2.5
AS28DRV4037
25
16
25
–50
25
–50
25
–50
16
–25
M6
2.5
AS28DRV4045
35
16
35
–70
35
–70
35
–70
16
–35
M8
10
AS28DRV4055
50
25
35
–70
35
–70
35
–70
16
–35
M8
10
AS28DRV4075
70
35
35
–70
35
–70
35
–70
16
–35
M8
10
AS28DRV4090
95
50
70
–120
70
–120
70
–120
50
–70
M12
35
AS28DRV4110
120
70
70
–120
70
–120
70
–120
50
–70
M12
35
AS28DRV4132
185
95
95–300
95–300
95–300
95–240
Nuts are used as
terminals, so it is
recommended that
you use a wrench
or sleeve.
AS28DRV4160
240
120
95–300
95–300
95–300
120–240
AS28DRV4185 95×2P
95
95–150
70–150
70–150
35–95
AS28DRV4200 95×2P
120
95×2P
–150×2P
95×2P
–150×2P
95×2P
–150×2P
120–240
AS28DRV4220 150×2P
150
95×2P –
150×2P
95×2P –
150×2P
95×2P –
150×2P
150–240
AS28DRV4250 95×4P 95×2P
95×4P
–150×4P
95×4P
–150×4P
95×4P
–150×4P
95×2P
–150×2P
AS28DRV4280 95×4P 95×2P
95×4P
–150×4P
95×4P
–150×4P
95×4P
–150×4P
95×2P
–150×2P
AS28DRV4315 95×4P 95×4P
95×4P
–150×4P
95×4P
–150×4P
95×4P
–150×4P
95×2P
–150×2P
AS28DRV4350 95×4P 95×4P
95×4P
–150×4P
95×4P
–150×4P
95×4P
–150×4P
95×2P
–150×2P