DRV-28 inverter
s
-254-
Storage time
Operation principle
Charge the inverter at 25% of the rated voltage for 30 minutes, and
then charge it at 50% of the rated voltage for 30 minutes, at 75% for
another 30 minutes, and finally charge it at 100% of the rated voltage
for 30 minutes.
More than 3 years
Use a voltage controlled power supply to charge the inverter:
Charge the inverter at 25% of the rated voltage for 2 hours, and then
charge it at 50% of the rated voltage for 2 hours, at 75% for another 2
hours, and finally charge it at 100% of the rated voltage for 2 hours.
The method for using a voltage controlled power supply to charge the inverter is described as follows:
The selection of a voltage controlled power supply depends on the power supply of the inverter. For
inverters with an incoming voltage of 1PH/3PH 230VAC, you can use a 230VAC/2A voltage regulator.
Both 1PH and 3PH inverters can be charged with a 1PH voltage controlled power supply (connect L+
to R, and N to S or T). All the DC bus capacitors share one rectifier, and therefore they are all
charged.
For inverters of a high voltage class, ensure that the voltage requirement (for example, 400V) is met
during charging. Capacitor changing requires little current, and therefore you can use a
small-capacity power supply (2 A is sufficient).
The method for using a resistor (incandescent lamp) to charge the drive is described as follows:
If you directly connect the drive device to a power supply to charge the DC bus capacitor, it needs to
be charged for a minimum of 60 minutes. The charging operation must be performed at a normal
indoor temperature without load, and you must connect a resistor in series mode in the 3PH circuit of
the power supply.
For a 400V drive device, use a resistor of 1 kΩ/100W. If the voltage of the power supply is no higher
than 400V, you can also use an incandescent lamp of 100W. If an incandescent lamp is used, it may
go off or the light may become very weak.
Fig 8.2 Charging circuit example of driving devices of 400V
8.4.2 Electrolytic capacitor replacement
Read the safety precautions carefully and follow the instructions to perform
operations. Otherwise, physical injuries or damage to the device may be
caused.
The electrolytic capacitor of an inverter must be replaced if it has been used for more than 35,000
hours. For details about the replacement, contact the local ASTOR office.