3. At the command prompt, type
commit
.
4. At the command prompt, type
reboot
.
5. Wait for the SMM-2 to initialize.
SMM-2 Serial Mode Connection
1. From a laptop computer USB port, connect a standard USB 2.0 A Male to Mini-B 5-pin
Male cable of any length to the SMM-2, as shown in Figure 7.5.
2. Start a terminal program, such as
PuTTY
Figure 7.26
PuTTY Configuration
Window
3. Click on the
Serial
button.
4. Determine the Serial line field COM port number from the Control Panel>Device
Manager>Ports (COM & LPT)>Gadget Serial (COM#) and modify if necessary to match
Note
To change the USB connection mode to Ethernet, replace "serial" with
"ethernet" in step 2 and proceed with the remaining steps listed above.
Note
The COM port number may change if the USB cable is moved to a different
USB port on the laptop computer.