1508685 Rev D
CHP Max Element Management Modules CHP-CMM, CMM-1, SMM, and SMM-1
6-37
Figure 6.28
FTP Transfer
Complete Message
FTP Failures
1. Bad file name:
The SMM version 1.1 software requires that the file names of the Images transferred be
SMMImage1.S19 and SMMImage2.S19. It will not allow any other file name to be
downloaded. The error message shown by the FTP session will report:
■
500 Requested download not completed, bad file
It will not prevent a user from copying a bad file to this file name and downloading it.
The FTP session only checks the file name.
2. Bad command:
The SMM version 1.1 software will only understand a “put” command so that software
can be downloaded to the module. If another command such as “get” is entered the
SMM will report:
■
200 PORT command successful
■
540 User banned or 502 Command not implemented
3. Incorrect user name or password
The SMM FTP session will only connect using the user name CCOR and the correct
password. If you attempt to log in with a different name or password the SMM will
report:
■
532 Login incorrect
■
Connection closed by remote host
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......