1508685 Rev D
CHP Max Monitorable Attributes
A-1
A P P E N D I X A
CHP MAX MONITORABLE ATTRIBUTES
CHP Max parameters can be monitored by accessing MIB objects via the SMM module's
SNMP Agent. The proprietary ARRIS MIB files are on the released CHP System CD or can be
downloaded from the ARRIS support web site. The MIB type indicates if the attribute is ARRIS
proprietary (ENTERPRISE) or if the attribute is contained in one of the standard IETF or
standard SCTE HMS MIBs supported by the CHP Max.
Table A.1 SMM-2 Parameters
Attribute
Parameter
MIB Object
MIB Type
SMM Param
Voltage
Major Low
Minor Low
Minor High
Major High
smmParamVoltage
ENTERPRISE
Table A.2 CMM(-1)/SMM(-1) Parameters
Attribute
Parameter
MIB Object
MIB Type
Module
Identification
Serial Number
Production Date
Firmware Version
Hardware Version
Service Tracking Number
entPhysicalSerialNum
chpSlotConfigModuleProductDat
e
entPhysicalSoftwareRev
entPhysicalHardwareRev
chpSlotStatusModuleServiceNu
m
STANDARD
ENTERPRISE
STANDARD
STANDARD
ENTERPRISE
Monitorable
Parameters
Backplane Voltage: 12V
DC
Backplane Voltage: 5V
DC
Backplane Voltage: 3.3V
DC
Backplane Voltage: –5V
DC
Internal Temperature
cmmParamVoltage
cmmParamVoltage
cmmParamVoltage
cmmParamVoltage
heCommonTemperature
ENTERPRISE
ENTERPRISE
ENTERPRISE
ENTERPRISE
STANDARD
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......