3-20
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
Rev D
Figure 3.11
Chassis Fan Bay
Module Identity Tab
Display
Fan 1-8 Current
Displays the 12V
DC
current of each of the eight chassis fans in mA.
Configure
Sets major low, minor low, minor high, and major high alarm limits of all
eight fan currents. Changing the alarm limit of one fan will change the
alarm limits of the other seven fans to the same alarm limit.
Show info
Lists the four alarm thresholds and graphical display configuration
information.
Show history
Displays a graph of the output current vs. time.
Save history
Saves output current data points vs. time to an Excel file format.
Module Identity tab
This tab only provides status. Refer to Figure 3.11 on page 3-20 to see the various module
parameters.
Alarms tab
This tab lists all major and minor alarms as shown in Figure 3.12 on page 3-21.
Table 3.6 Controls and Functions of the
Craft Management Software
(cont’d)
Control
Function
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......