CHP Max5000 Chassis (Rear Fiber Version)
2-21
Figure 2.11
Chassis Fan Bay
Status and Settings
Management
Window
Table 2.9 Controls and Functions of the
Craft Management Software
Control
Function
Status and Settings tab
Fan 1-8 Current
Displays the 12V
DC
current of each of the eight chassis fans in mA.
Configure
Sets major low, minor low, minor high, and major high alarm limits of all
eight fan currents. Changing the alarm limit of one fan will change the
alarm limits of the other seven fans to the same alarm limit.
Show info
Lists the four alarm thresholds and graphical display configuration
information.
Show history
Displays a graph of the output current vs. time.
Save history
Saves output current data points vs. time to an Excel file format.
Module Identity tab
This tab only provides status. Refer to Figure 2.12 on page 2-22 to see the various module
parameters.
Window resulting from right clicking
on Fan 1 current through Fan 8