10. When the next Internet Protocol (TCP/IP) Properties window appears, click on the
Use the following IP address:
option, then type the following addresses into the
following fields (refer to Figure 5.25):
–
IP address:
10.10.10.5
–
Subnet mask:
255.255.255.0
–
Default gateway:
10.10.10.1
Figure 7.25
Internet Protocol
(TCP/IP) Properties
Window
11. Click on the
OK
button.
Now you can use any telnet software (for example,
PuTTY
) to communicate via telnet with the
SMM-2.
To set the network information, proceed as follows:
1. After login, at the [email protected]> prompt, type
configure
and press the
Enter
key.
2. At the [email protected]% prompt, type
set interfaces
and press the
<TAB>
or
<SPACE>
followed by
?
to view all the parts of the IPv4 address command:
eth0
sets the IPv4 address
mask
sets the IP subnet mask
gateway
sets the default gateway
Note
The [email protected]> prompt is an example and the prompt you are likely
to see will be different.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......