B-16
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
1508685 Rev D
1.3.6.1.4.1.5591.1.11.2.1.1
.1.1.1.1.2.50002
.iso.org.dod.internet.private.enterp
rises.scteRoot.scteHmsTree.insideP
lantIdent.heBaseIdent.heCommon.
heCommonMib.heCommonObjects
.heCommonParams.heCommonTa
ble.heCommonEntry.heCommonTe
mperature.50002
Receiver Internal Temperature
Alarm
1.3.6.1.4.1.2907.20.2.1.1.1
.2.2.1.1.50002.2
.iso.org.dod.internet.private.enterp
rises.ccor-reg-ident.ccorHeadend.c
corHeadendMIB.chpMax5000MIB.c
hpCommonMIB.chpCommonMIBO
bjects.chpMaxSlots.chpSlotStatusT
able.chpSlotStatusEntry.chpSlotStat
usPhysicalState.50002
Module Communication Status
Down
Module Removed
Module Communication
1.3.6.1.4.1.2907.20.2.1.7.1
.2.1.2.50002.1.1
.iso.org.dod.internet.private.enterp
rises.ccor-reg-ident.ccorHeadend.c
corHeadendMIB.chpMax5000MIB.c
hpRxMIB.rxMIBObjects.rxChCtlTabl
e.rxChCtlEntry.rxChCtlRfStatus.500
02.1
The selected Rx output was set to
enable.
The selected Rx output was set to
low.
The selected Rx output was set to
off.
1.3.6.1.4.1.2907.20.2.1.7.1
.2.1.2.50002.1.2
.iso.org.dod.internet.private.enterp
rises.ccor-reg-ident.ccorHeadend.c
corHeadendMIB.chpMax5000MIB.c
hpRxMIB.rxMIBObjects.rxChCtlTabl
e.rxChCtlEntry.rxChCtlRfStatus.500
02.1
The selected Rx output was set to
enable.
The selected Rx output was set to
low.
The selected Rx output was set to
off.
1.3.6.1.4.1.5591.1.11.1.2.1
.1.1.1.4.50002.1.2
.iso.org.dod.internet.private.enterp
rises.scteRoot.scteHmsTree.insideP
lantIdent.heOptics.heOpticalReceiv
erGroup.heOpticalReceiverMIB.he
OpRxMIBObjects.heOpRxInputTabl
e.heOpRxInputEntry.heOpRxInputS
tatus.50002.1
Rx A Optical Input Status Alarm
Rx B Optical Input Status Alarm
Table B.3 FRX Module
heCommonLogOID
MIB
heCommonLogText
1.3.6.1.4.1.5591.1.11.1.2.1
.1.1.1.2.50008.1
.iso.org.dod.internet.private.enterp
rises.scteRoot.scteHmsTree.insideP
lantIdent.heOptics.heOpticalReceiv
erGroup.heOpticalReceiverMIB.he
OpRxMIBObjects.heOpRxInputTabl
e.heOpRxInputEntry.heOpRxInputP
ower.50008.1
Rx A Optical Input Power Alarm
Rx B Optical Input Power Alarm
Table B.2 2RRX, R2RRX and R2RRFF Modules (cont’d)
heCommonLogOID
MIB
heCommonLogText
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......