CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
1508685 Rev D
Installation of CHP Max
Craft Management Software
➤
To install the CHP Max Craft Management Software refer to Installing CHP Max Craft
CHP Max System Management Module
CHP Max System Management Module (SMM) remotely monitors and controls application
modules installed in the same chassis and the application modules installed in up to nine
additional chassis. The SMM is an SNMP Agent that can communicate with SNMP Managers
typically located in the Network Operating Center (NOC). The SMM provides the following
features:
■
Communicates with CMM via RS-485 daisy chain
■
Communicates with SNMP Manager in NOC via Ethernet
■
Supports all SNMP functions and HMS functions including downloads and trap
handling
■
Supports all released indoor plant equipment MIBs (can be downloaded from
www.scte.org)
–
ANSI/SCTE 36 2002R2007 SCTE-ROOT
–
ANSI/SCTE 37 2010 SCTE-HMS-ROOTS
–
ANSI/SCTE 38-1 2009 SCTE-HMS-PROPERTY
–
ANSI/SCTE 38-8 2009 SCTE-HMS-DOWNLOAD
–
ANSI/SCTE 38-11 2008 SCTE-HMS-HEADENDIDENT-MIB
–
ANSI/SCTE 83-1 2006 SCTE-HMS-HE-OPTICS-MIB
–
ANSI/SCTE 83-4 2009 SCTE-HMS-HE-RF-MIB
–
ANSI/SCTE 84-1 2009 SCTE-HMS-HE-COMMON-MIB
–
ANSI/SCTE 84-2 2009 SCTE-HMS-HE-POWER-SUPPLY-MIB
–
ANSI/SCTE 84-3 2009 SCTE-HMS-HE-FAN-MIB
–
ANSI/SCTE 85-1 2009 SCTE-HMS-HE-OPTICAL-TRANSMITTER-MIB
–
ANSI/SCTE 85-2 2009 SCTE-HMS-HE-OPTICAL-RECEIVER-MIB
–
ANSI/SCTE 85-3 2009 SCTE-HMS-HE-OPTICAL-AMPLIFIER-MIB
–
ANSI/SCTE 94-1 2009 SCTE-HMS-HE-RF-AMP-MIB
■
Supports ARRIS proprietary MIBs
■
SNMP v2/v3 compatible and complies with IETF and SCTE-HMS standards
Installation/Replacement of the CMM or SMM
CAUTION
The SMM must be installed into a chassis with a label containing
CHP-CHASSIS-19 on the right front flange of the chassis. If label is not located on the
front right flange, do
NOT
install the SMM into the chassis. Installation of the SMM
into a chassis without a label on the right front flange (label with 961015726201 on
right side) will damage the SMM and void the warranty.
Note
Ensure that the desired Power Supply configuration is installed before
installing the SMM.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......