4-2
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
Rev D
The CHP Max AC power supply (P/N CHP-PS/AC1-Q-NP) is intended for international
customers who cannot use the US standard power cord. No power cord is included and the
customer must order the appropriate power cord separately (refer to Table 4.1 on page 4-2).
Although each chassis requires only one power supply, the CHP chassis accepts two power
supplies. Isolated outputs allow the primary and redundant supplies to operate in a
power-sharing configuration. Should the primary power source fail, a second power supply
provides all necessary DC power.
Figure 4.1
AC Power Supply
The module converts the AC input into four DC voltages: +12.0V
DC
, +5.0V
DC
, +3.5V
DC
, and
–5.0V
DC
. These voltages pass through the DC output connector on the rear of the power
supply to the chassis backplane, which routes them to the installed application modules.
Integrated management circuitry provides digital representations of internal temperature,
power supply output voltages, and fan current for status monitoring. Management signals
enter and exit through the multi-pin connector on each power supply’s rear panel.
The CHP-PS/AC1-Q and CHP-PS/AC1-SW AC input power supplies include a power cord for
115V
AC
United States installations. Other available power cords are listed in the following
table for installations in countries that do not use the 115V
AC
United States plug.
Table 4.1 AC Power Supply Power Cords
Description
Part Number
Australia Power Cord, C13, 2.5 meters, 10 amp
110543
Continental Europe Power Cord, C13, 2.5 meters, 10 amp
110542
Switzerland Power Cord, C13, 2.5 meters, 10 amp
0465346-7
United States Power Cord, AC/IEC 8 foot, FEM 11
37121-1000
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......