2-4
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
Rev D
3. Keep all packing materials until your inspection is complete. When possible, save the
shipping container for future reshipment and/or storage.
If damage is discovered, file a claim with the carrier immediately and notify your ARRIS
representative as soon as possible. Product deemed defective by the original purchaser must
be returned to ARRIS prepaid in the original packing material (or equivalent) with a Return
Material Authorization (RMA) from ARRIS Customer Service (800-233-2267).
Precautions
Failure to comply with these general safety precautions and with the specific precautions
described elsewhere in this manual violates the safety standards of the design, manufacture,
and intended use of the device. ARRIS assumes no liability for the customer’s failure to
comply with these precautions.
Chassis Options
The CHP Max5000 chassis (P/N CHP-CHASSIS-19, CHP-CHASSIS-19Q, CHP-CHASSIS-19S, or
CHP-CHASSIS-19U) mounts directly into a standard 19-inch rack. An optional bracket kit
(P/N CHP-EXTBKT-23) is sold separately to mount the chassis in a 23-inch rack.
A Backplane Ethernet Switch (P/N CHP-BP-ETH-SW) is optional and is only used for
high-speed applications such as CHP ePON OLT. It should be ordered separately.
Note
For best performance, ARRIS recommends daisy-chaining a maximum of 5
chassis together; 6 to 10 may be daisy-chained together, but it will impact
performance.
CAUTION
Do not operate the chassis and installed modules in an ambient
environment above 50º C (122ºF) or below 0° C (32°F) or with noncondensing
relative humidity above 90% or below 10%. Doing so may result in unsatisfactory
performance, unit failure, shortened unit life span, or a safety hazard.
CAUTION
Do not attempt to modify or service any part of this chassis not
specifically referred to as replaceable in this manual. Doing so voids the warranty.
Return the chassis to ARRIS for service and repair.
CAUTION
Store the chassis and modules away from corrosive materials at a
temperature between –40 and 70ºC (–40 and 158ºF) and with no more than 90%
humidity, noncondensing.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......