3-6
CHP Max™ Headend Optics Platform Chassis, Controllers and Power Supplies
Rev D
Table 3.3 CHP Max5000 Chassis Connectors and Fans
Connectors
Description
DC/Communication
Connectors
Multi-pin connectors on chassis backplane carry DC power (via DC bus)
and communication signals (via SPI bus) into and out of application
modules.
Shelf Interconnect
On all models except the CHP-CHASSIS-R-19U, RJ-14 connectors permit
“daisy-chaining” up to 10 chassis together for remote monitoring of
these chassis. One SMM module is required to interface with up to 9
CMM-equipped chassis. For best performance, ARRIS recommends
daisy-chaining a maximum of 5 chassis together; 6 to 10 may be
daisy-chained together, but it will impact performance.
Hi Speed Shelf
Interconnect
On model CHP-CHASSIS-R-19U only, RJ-14 connectors permit
“daisy-chaining” up to 10 chassis together for remote monitoring of
these chassis. One SMM module is required to interface with up to 9
CMM-equipped chassis. Intended for high speed applications; requires
installation of optional Backplane Ethernet Switch P/N CHP-BP-ETH-SW.
For best performance, ARRIS recommends daisy-chaining a maximum of
5 chassis together; 6 to 10 may be daisy-chained together, but it will
impact performance.
Lo Speed Shelf
Interconnect
On model CHP-CHASSIS-R-19U only, RJ-14 connectors permit
“daisy-chaining” up to 10 chassis together for remote monitoring of
these chassis. One SMM module is required to interface with up to 9
CMM-equipped chassis.
Ethernet SNMP Interface
(10BaseT)
An RJ-45 interface carries management signals from the chassis to a
remote EMS controller.
Local Alarm Terminal
Block
Access terminals for external alarms.
Please note that the contacts on
the terminal block are reversed.
RF Connector Locations
RF connectors on rear of application modules slide through these holes
in the chassis. Additional hardware is required to secure application
modules.
Ground Studs
Connect to earth ground.
Retaining Tabs
Secure power supply modules; press tab to remove power supply.
Fan Assemblies
Eight independent, field-replaceable assemblies (single-speed P/N
0625734-1; dual-speed P/N CHP-QFANKIT) for cooling.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......