Rev D
System Management Module 2 (SMM-2)
7-13
To remove the SMM-2:
Press upward on the latch release on the front panel (refer to Figure 5.3 on page 5-9) and
slide the module out the front of the chassis.
Module Communication Connections
There are two ways to connect to the SMM-2:
■
TELNET: Using the CHP chassis Ethernet RJ-45 port
■
USB Mode: Using the SMM-2's Mini-USB connector on the front panel of the module
TELNET Connection Instructions
To make a TELNET connection:
1. From a laptop computer, change the local area connection information to the
following:
IPv4 address: 192.168.1.5 (recommended setting)
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.254
2. Connect an Ethernet cable from the laptop computer to the CHP chassis Ethernet
RJ-45 port, as shown in Figure 7.5.
Note
In CHP System version 4.10 or later, the IP address of Ethernet over USB mode
is assigned (10.10.10.1) as the default and can be configured or changed. The
SMM-2 management network must not be in the same subnet as the default IP
address for the USB Ethernet mode to work.
In CHP System version 4.9 or earlier, the IP address of Ethernet over USB mode is
hard-coded (192.168.1.2) as the default and cannot be configured or changed. The
instructions below for the Ethernet over USB mode still apply, but can only be
implemented using the 192.168.1.2 IP address in CHP System version 4.9 or earlier.
CAUTION
In order to access the high speed functionality provided by the
backplane, the SMM-2 must be installed in a chassis with a label containing
CHP-CHASSIS-19U or CHP-CHASSIS-R-19U on the right front flange of the chassis and
the optional Backplane Ethernet Switch (P/N CHP-BP-ETH-SW).
Note
Status and control of modules will not be available when the SMM-2 is
removed.
Note
Initial communication must be established using the TELNET CONNECTION
INSTRUCTIONS for an SMM-2 module shipped from the factory or any SMM2 that is
configured for the 192.168.1.x network.
Summary of Contents for CHP Max5000
Page 2: ......
Page 12: ...x CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 100: ...4 18 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 120: ...5 20 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies Rev D...
Page 199: ...Rev D System Management Module 2 SMM 2 7 33 Figure 7 28 Add CHPMax5000 Device Window...
Page 261: ...1508685 Rev D CHP Max Trap Information B 29...
Page 262: ...B 30 CHP Max Headend Optics Platform Chassis Controllers and Power Supplies 1508685 Rev D...
Page 266: ......