3 . Changing the Equipment Settings
91
MF-C2000A Series
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
LASER CONTROL OPTION PARAMETERS
How to see the displayed items
: Settable item
LD AUTO
START
Sets the LD to ON or OFF. At ON, a LD becomes ON at AUTO START and the
screen is displayed in the status of LD: ON.
NG LASER
STOP
At ON, the LD and the BEAM are turned OFF when error No.035/LASER POWER
OUT OF RANGE occurs and a laser stops.
LASER
START
DELAY
Sets the acceptance time for laser start signal and schedule signal from 0.1 ms, 1
ms, 2 ms, 4 ms, 8 ms, or 16 ms.
GUIDE
BLINK
Sets the guide light blinking status or continuous lighting to ON or OFF.
EXT-IO
PULSE
WIDTH
Sets the output time for end signal and monitor normal/trouble signal from 20 ms, 30
ms, or 40 ms.
CW SLOPE
CHK
DISABLE
Sets the slope portion to be monitored or not in the CW envelope monitoring (moni-
toring laser in range). At ON, the slope portion is not monitored.
X
Returns to the CONFIG screen.
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......