238
MF-C2000A Series
1 . Error Display and How to Take a Measure
No .
Contents of error
LD
Alarm
output
Measures
215
INTERNAL UNIT TEMP ERROR
(A02)
OFF
ON
Increase the cooling water flow rate.
Check the cooling water flow normally.
If this error happens often, consult us.
216
LD CURRENT HIGH (A03)
OFF
ON
Overcurrent of the LD.
Restart the Laser. If this error happens often, con-
sult us.
217
OUTPUT POWER LOW (A04)
OFF
ON
The optical circuit is wrong.
Consult us.
218
ILLEGAL USE (A05)
-
-
Invalid operation in self-checking at warming-up.
Restart in accordance with the operation manual.
219
FIBER OUTPUT UNIT ERROR
(A06)
OFF
ON
Check the feed fiber broken.
Check that the optical fiber is connected correctly.
If you can't reset this error, consult us.
220
ENGINE ERROR (A08)
OFF
ON
The communication error occurs between internal
units.
If this error happens often by restarting, consult us.
221
OUTPUT POWER HIGH (A10)
OFF
ON
The power output is too high. → P.222
Adjust the power setting to reduce back reflection.
222
INTERNAL UNIT OPEN (A14)
OFF
ON
The cover of inner unit is opened.
Consult us.
223
INTERNAL UNIT OUTPUT POWER
HIGH (A17)
OFF
ON
The power output is too high. → P.222
Adjust the power setting to reduce back reflection.
224
INTERNAL UNIT OUTPUT POWER
LOW (A18)
OFF
ON
The optical circuit of inner unit is wrong.
Consult us.
225
ILLEGAL LASER OUTPUT (A19)
OFF
ON
The inner unit is wrong.
Consult us.
226
ILLEGAL TEMP.&HUMID-METER
INPUT
OFF
ON
Check the TEMP.&HUMID-METER or the connec-
tion.
If the TEMP.&HUMID-METER is OK and the error
reoccurs, consult us.
228
GUIDE BEAM WARNING (W11)
-
-
The warning of guide light ON/OFF is given.
Retry several minutes later. If this warning hap-
pens again, consult us.
238
FEED-FIBER BURNED (A23)
OFF
ON
The feed fiber is burnt out.
Restart the Laser. If this error happens often, con-
sult us.
239
COMBINER UNIT ALARM (A24)
OFF
ON
The combiner unit fault.
Restart the Laser. If this error happens often, con-
sult us.
250
DRY-AIR UNIT WARNING
-
-
The Warning signal has ON in the Dry-air unit.
Check the Dry-air unit below the unit manual.
251
DRY-AIR FILTER WARNING
-
-
The filter-warning has occurred in the Dry-air unit.
Check the filter.
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......