236
MF-C2000A Series
1 . Error Display and How to Take a Measure
No .
Contents of error
LD
Alarm
output
Measures
070
BCMD ERROR IN LASER UNIT
OFF
ON
The laser unit could not execute the command.
Consult us.
078
LD-ON TIMEOUT
-
-
A timeout occurred in Oscillator reply “LD ON.”
Check the KEY-SWITCH on attached to the oscilla-
tor. If the KEY-SWITCH is on, consult us.
079
LASER ERROR SIGNAL ERROR
OFF
ON
An oscillator error signal of unknown cause has
been detected.
Consult us.
080
OSCILLATOR NOT READY
OFF
ON
The oscillator has not started normally.
Consult us.
082
ILLEGAL OSCILLATOR SIGNAL
OFF
ON
A signal from the oscillator is abnormal.
Consult us.
086
AHC TARGET-TEMP. SETTING ER-
ROR
OFF
ON
The "AHC TARGET-TEMP." setting is out of range
in this schedule.
Check the setting.
163
ILLEGAL WARNING SIGNAL
-
-
An oscillator warning signal of unknown cause has
been detected. The laser equipment may recover
normally before the warning type is identified.
Consult us.
164
LASER STOP2
OFF
ON
The REM. I/L connector circuit is opened.
Eliminate the cause of trouble and close the pin.
165
LD POWER SUPPLY ERROR
OFF
ON
An error has occurred with the LD power supply.
Consult us.
166
LD CURRENT OVERLOAD
OFF
ON
Overcurrent of the LD.
Consult us.
182
BRANCH UNIT MOTOR TEMP ER-
ROR
OFF
ON
Abnormal motor temperature of the branch unit.
After waiting for several minutes, press the TROU-
BLE RESET button. If the trouble will continue even
after the above measures, consult us.
183
BRANCH UNIT DUMPER TEMP
ERROR
OFF
ON
Abnormal dumper temperature of the branch unit.
After waiting for several minutes, press the TROU-
BLE RESET button. If the trouble will continue even
after the above measures, consult us.
185
186
BRANCH MIRROR 1 OPEN TROUBLE
BRANCH MIRROR 2 OPEN TROUBLE
OFF
ON
The timesharing unit fault or a start signal is input
while timesharing unit is operating.
Extend the time from input of beam select signal to
input of laser start signal. If the trouble will continue
even after the above measures, consult us.
188
189
BRANCH MIRROR 1 CLOSE TROUBLE
BRANCH MIRROR 2 CLOSE TROUBLE
OFF
ON
The timesharing unit fault or a start signal is input
while timesharing unit is operating.
Extend the time from input of beam select signal to
input of laser start signal. If the trouble will continue
even after the above measures, consult us.
192
SHUTTER/BEAM-CHECK FAILED
OFF
ON
The shutter/beam-check is not finished normally.
If it hasn’t been better by restarting, consult us.
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......