5 . Monitoring Output
137
MF-C2000A Series
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
⇒
When the total laser output time is higher than 0.5 s in the CW mode, set
“HIGH” and “LOW” at the ratio of output (SET POWER × POWER [%]) set on
the SCHEDULE screen. The following formula is given to convert the set value
into Watts. POWER [%] is also increased or decreased according to the output
increase/decrease between each POINTs. When the measured value of the
monitored laser light is out of the range shown by red lines below, error No.035/
LASER POWER OUT OF RANGE occurs.
Output
Time
Controlled
waveform
SET POWER (1) × POWER [%] (2) / 100 ×
HIGH [%] (3) / 100
SET POWER (1) × POWER [%] (2) / 100 ×
LOW [%] (4) / 100
(1)
(2)
(3)
(4)