2 . Maintenance of the Laser Oscillator
⇒
The UP/DOWN adjustment is effective only when “PRESS UP/DOWN” is dis-
played. When UP is clicked beyond the rated output, error No.221/OUTPUT
POWER HIGH (A10) or No.223/INTERNAL UNIT OUTPUT POWER HIGH (A17)
occurs. Confirm that the measurement of the power meter is proper.
⇒
Make the UP/DOWN adjustment within the range of gauge (100 to 110). The
number of times of operation is limited to 5 times. If more adjustment is needed,
proceed to Step (4) to set the “LD” setting button to ON and check the laser out-
put and then make the UP/DOWN adjustment again.
⇒
Since the adjustment range (100 to 110) is displayed by an integer, the displayed
numeral value may not change even if the buttons are pressed, but it actually
changes by approx. 0.5 to 2%.
CAUTION
The laser power correction function is for restoring the lowered output . Make sure
not to exceed the rated output . It will not coverd by the warranty even if it is still
within the warranty period since it causes a high load and the product lifetime is
shortened .
(4) Press the “LD” setting button to set it to ON.
Confirm that the LD is turned ON and press the
button.
(5) Press the LASER START/STOP button of the laser controller.
Check the display on the power meter and confirm that the laser is emitted. After
recording the power meter display, press the
button.
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......