4 . Setting the Laser Light Output Schedule
EXPERT SETTINGS
How to see the displayed items
: Settable item
CORRECTION
Sets the correction factor in the range of 0.05 to 1.00.
MONITOR SPAN
Sets the display time of the temperature waveform on the MONITOR screen.
Display time of the temperature waveform = laser emission time × MONITOR
SPAN (Setting range: 1.0 to 2.0)
<Note>
In the CW waveform, the display of the temperature waveform is finished at
the time when the following operation is performed for the laser waveform
with 500 ms.
- Laser stops by the laser stop signal input within the time set in a schedule.
- The next laser output starts.
- The output setting or number of schedule is changed.
- An error occurs.
KEEP POW .
Sets the output in KEEP operation in the range of 0 to 100%.
SMOOTHING
Sets the moving average time of the measured temperature from 0.0001,
0.001, 0.01, 0.1, or 0.2 s. When the temperature change is large and it is
hard to read, increase the set time. The variation is displayed smaller.
CLOSE
Returns to the ACTIVE HEAT CONTROL screen.
Time
Input
value
Smoothing
Input signal
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......