MF-C2000A Series
2 . Maintenance of the Laser Oscillator
(4) Press the “POWER-CORRECT ASSIST (OPTION)” setting button and set to
USE to restart the equipment.
2
Inputting the Measurement Conditions
(1) Press the “SCHEDULE” setting button.
Enter the SCHEDULE number by using the “<” and “>” buttons or numeric key-
pad and then press the ENT key.
(2) Press the “FORM” setting button to set “CW.”
(3) Press the “SET POWER” setting button.
Enter the laser output set value by using the numeric keypad and then press the
ENT key.
<Note>
Set the laser output value around the rated output after measuring with a low val-
ue . Refer to “Inspecting the Laser Output” on page 218 .
(4) Press the laser output time “TIME [sec]” and laser output value “POWER [%]”
setting buttons of “POINT 01” to “POINT 05.”
Enter each value by using the numeric keypad and then press the ENT key.
⇒
Due to characteristics of the power meter, it takes several seconds until the mea-
surement value is stabilized after emission. It is recommended to set it to 60 to
100 sec.