248
MF-C2000A Series
Specifications
Item
MF-C2000A-M/MC
MF-C2000A-S/SC
Power
Supply
Breaker rated current
(to be supplied by customers)
For the power supply side, we earnestly recommend using a leak-
age breaker with the rated current of 40 A or more, which is appli-
cable to harmonics and surges.
Ground
Class D (ground resistance: 100 Ω max.)
Laser
Controller
Number of schedules
256
Schedule
setting
REPEAT mode
Laser output waveform
Laser energy for upper/lower limit judgment
Number of outputs per second
Number of repeated outputs
Modulation output waveform (when using the modulation function)
CW mode
Laser output waveform
Modulation output waveform (when using the modulation function)
Measurement function
Laser energy (J), Average power (W)
Counter
Displays the total number of outputs (9 digits)
Displays the number of acceptable outputs (9 digits)
Displays the total LD ON time (7 digits)
Displays the laser output time (7 digits)
Cable length
Standard 1 m
Display language
Japanese and English (switchable)
Active heat control function
(option)
Detecting range of heat detector 1: 140 to 700°C
Detecting range of heat detector 2: 260 to 3000°C
<Note>
Either the heat detector 1 or 2 can be selected.
The temperature is not a warranty value. Since it may change de-
pending on the workpiece material or the surface condition, use it
as a guide.
Effective only when using the laser main unit corresponding to the
active heat control with the output unit.
Operating
Environ-
ment
Ambient temperature
5 to 40°C
Ambient humidity
20% to 85% RH (non-condensing)
<Note>
For the upper limit of ambient humidity, refer to page 46.
Temperature during transport or
storage
-10 to 50°C (with cooling water removed)
Humidity during transport or
storage
20% to 90% RH
Vibration during transport
4.9 m/s
2
(0.5 G) max.
Impact during transport
49 m/s
2
(5 G) max.
Vibration during operations
10 to 60 Hz: 0.98 m/s
2
(0.1 G) max.
Intermittent vibration during
operations
Less than 2 Hz : 4.9 m/s
2
(0.5 G) max.
Pollution degree *2
2
Altitude
2000 m or less
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......