66
MF-C2000A Series
9 . Connecting the Scanner Head Unit
9 . Connecting the Scanner Head Unit (MF-C2000A-MC/
SC Only)
This section explains how to connect the scanner head unit .
Item required
Phillips screwdriver
Operating Procedure
(1) Confirm that the MAIN POWER switch is turned OFF.
(2) Connect the scanner power cable to the SCAN POWER connector on the con-
nector panel 2.
(3) Connect the scanner control connecting cable to the SCANNER connector on the
connector panel 2.
(4) Connect the scanner power cable to the power supply connector on the scanner
head unit.
(5) Connect the scanner control connecting cable to the head I/F connector (XY2-100)
on the scanner head unit.
CL-H601A
CL-H201A
Power supply connector
Power supply connector
Head I/F connector (XY2-100)
Head I/F connector (XY2-100)
SCANNER connector
SCAN POWER connector