108
MF-C2000A Series
4 . Setting the Laser Light Output Schedule
REPEAT
Sets the number of laser light outputs per second in the range of 1 to 1000 pps
(pulse per second).
SHOT
Sets the number of laser outputs in the range of 1 to 9999.
When the laser output count reaches the set value, the laser output is stopped.
When 1 is set, a single-shot output is performed. When 9999 is set, laser light is
continuously output until a laser stop signal is input.
Fn
When this button is pressed, a window to select function is displayed and the fol-
lowing editorial assistant functions can be used.
RESET: Initializes the currently-selected schedule.
COPY:
Copies the currently-selected schedule to a temporary memory buffer.
PASTE:
Restores data from a temporary memory buffer to the currently-select
-
ed schedule.
⇒
For the common items in the upper/lower part of the screen, refer to page 81.
<Notes>
- The laser output value (%) setting range is 0 to 200% . However, the laser output
value cannot be set exceeding the maximum value of “SET POWER” x 100% . If the
laser output value is set to 100%, the value set in “SET POWER” is selected .
- There are limitations of the total time of the laser output time COOL1 +
COOL2 + FLASH3 in combination with values of SET POWER and RE-
PEAT . For details, refer to “Limitations of Schedule Setting” on page 132 .
- Within the range of 10% of the maximum SET POWER, a constant power is output
to protect the laser oscillator without reference to waveform input . For details,
refer to “Limitations of Schedule Setting” on page 132 .
Preliminary Oscillation
For MF-C2000A-M/S, to stabilize the laser oscillation, the minimum power of laser (100
W) is output for 0.5 ms immediately before laser output. The preliminary oscillation
is performed during the non-laser output time, but when the interval of time between
laser outputs is shorter than 0.8 ms, the preliminary oscillation cannot be performed
and the minimum power of laser is output during the set time. The non-laser output
time is any of the following:
• Laser output time (ms) whose laser output value (%) is set to 0%
• Set time of COOL1/COOL2
• Time interval between laser outputs set for REPEAT (*)
*: When the interval of time between laser outputs is shorter than 0.8 ms, the mini-
mum power of laser is also output during other non-laser output times.
Non-laser output time 0 .8 ms or longer Shorter than 0 .8 ms
100%
Minimum power
Summary of Contents for MF-C2000A Series
Page 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Page 21: ...Introduction Part ...
Page 22: ......
Page 34: ......
Page 42: ......
Page 43: ...Installation and Preparation Part ...
Page 44: ......
Page 73: ...Operating Part ...
Page 74: ......
Page 78: ......
Page 142: ......
Page 212: ......
Page 213: ...Maintenance Part ...
Page 214: ......
Page 232: ......
Page 244: ......
Page 245: ...Appendixes ...
Page 246: ......