162
MF-C2000A Series
3 . Connector Functions
Emergency Stop for Complicated Systems
Interfacing with External Emergency Stop Circuitry
User Supplied Safety Relay Module(s) Required
Complicated Systems are those in which more than one emergency stop sub-circuit
must be linked together. An example of this would be a machine that has a Laser,
parts handler with pneumatic controls, PLC, and conveyor belt all of which have ES-
TOP buttons where one ESTOP button stops all devices. Any situation in which more
than one device must be connected together and respond identically to an emergen-
E-STOP Connector
ES
TO
P
E
ST
O
P
ESTOP CH2 rtn
ESTOP CH 2
ESTOP CH 1
ESTOP Out 1a
ESTOP Out 1b
ESTOP Out 2a
ESTOP Out 2b
Inside the laser
User ESTOP Wiring
19
14
18
1
16
6
3
5
8
9
21
22
12
25
11
ESTOP CH1 rtn
Interlock rtn 2
Interlock out 2
Interlock rtn 1
Interlock out 1
24
(Open and close two
contacts simultaneously.)
User Interlock Wiring
(dry contact closure)
E-STOP Connector