Fieldbus control with fieldbus adapter 345
References
References (REF) are 16-bit signed integers. A negative reference (indicating
reversed direction of rotation) is formed by calculating the two’s complement from the
corresponding positive reference value. The contents of each reference word can be
used as speed or frequency reference.
Actual values
Actual values (ACT) are 16-bit words containing information on selected operations of
the drive.
Communication profile
The communication between the drive and the fieldbus adapter supports the DCU
communication profile. The DCU profile extends the control and status interface to 32
bits.
For the DCU profile Control and Status word contents, see section
on page
Fieldbus
network
Fieldbus adapter
Data conversion
Drive
Industry standard drive
profile
(eg, PROFIdrive)
Data conversion
ABB drives
Transparent 16
Optional reference,
actual value scaling
Transparent 32
Select
2)
1)
1)
1)
DCU profile
2)
Selection through fieldbus adapter configuration parameters (parameter group
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...