Fault tracing 355
5029
Memory is not ready.
Retry.
5030
Invalid request
Contact your local ABB representative.
5031
Drive is not ready for
operation, eg, due to low
DC voltage.
Check input power supply.
5032
Parameter error
Contact your local ABB representative.
5040
Parameter download error.
Selected parameter set is
not in current parameter
backup file.
Perform upload function before download.
5041
Parameter backup file
does not fit into memory.
Contact your local ABB representative.
5042
Parameter download error.
Selected parameter set is
not in current parameter
backup file.
Perform upload function before download.
5043
No start inhibit
5044
Parameter backup file
restoring error
Check that file is compatible with drive.
5050
Parameter upload aborted
Retry parameter upload.
5051
File error
Contact your local ABB representative.
5052
Parameter upload has
failed.
Retry parameter upload.
5060
Parameter download
aborted
Retry parameter download.
5062
Parameter download has
failed.
Retry parameter download.
5070
Panel backup memory
write error
Contact your local ABB representative.
5071
Panel backup memory
read error
Contact your local ABB representative.
5080
Operation is not allowed
because drive is not in
local control mode.
Switch to local control mode.
5081
Operation is not allowed
because of active fault.
Check cause of fault and reset fault.
5083
Operation is not allowed
because parameter lock is
on.
Check parameter
setting.
5084
Operation is not allowed
because drive is
performing a task.
Wait until task is completed and retry.
5085
Parameter download from
source to destination drive
has failed.
Check that source and destination drive types
are same, ie, ACS355. See type designation
label of the drive.
5086
Parameter download from
source to destination drive
has failed.
Check that source and destination drive type
designations are the same. See type
designation labels of the drives.
ALARM CODE CAUSE
WHAT TO DO
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...