Program features 133
Programmable analog output
One programmable current output (0…20 mA) is available. Analog output signal can
be inverted, filtered and the maximum and minimum values can be adjusted. The
analog output signals can be proportional to motor speed, output frequency, output
current, motor torque, motor power, etc. The update cycle for the analog output is
2 ms.
Analog output can be controlled with Sequence programming. It is also possible to
write a value to an analog output through a serial communication link.
Settings
Diagnostics
Parameter
Additional information
Group
AO value selection and processing
Group
AO in motor temperature measurement
/
8433
/…/
8493
AO control with Sequence programming
Actual signal
Additional information
AO value
AO control values defined by Sequence programming
Fault
Incorrect AO signal scaling (
Summary of Contents for ACS355 series