Fieldbus control with embedded fieldbus 331
8
AT_SETPOINT
1
OPERATING
.
Actual value equals reference value (= is
within tolerance limits, ie, in speed control the difference
between the output speed and the speed reference is less
than or equal to 4/1%* of the nominal motor speed).
* Asymmetric hysteresis: 4% when speed exits the
reference area, 1% when speed enters the reference area.
0
Actual value differs from reference value (= is outside
tolerance limits).
9
REMOTE
1
Drive control location: REMOTE (EXT1 or EXT2)
0
Drive control location: LOCAL
10
ABOVE_LIMIT
1
Supervised parameter value exceeds the supervision high
limit. Bit value is 1 until the supervised parameter value falls
below the supervision low limit. See parameter group
, parameter
0
Supervised parameter value falls below the supervision low
limit. Bit value is 0 until the supervised parameter value
exceeds the supervision high limit. See parameter group
, parameter
11
EXT CTRL LOC
1
External control location EXT2 selected
0
External control location EXT1 selected
12
EXT RUN
ENABLE
1
External Run enable signal received
0
No external Run enable received
13
…
15
Reserved
ABB drives profile (EFB) Status word, parameter
5320 EFB PAR 20
Bit
Name
Value
STATE/Description
(Correspond to states/boxes in the state diagram)
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...