288 Actual signals and parameters
RS-485
FSCA-01 RS-485 adapter module
485
5102 FB PAR 2
These parameters are adapter module-specific. For more
information, see the module manual. Note that not all of
these parameters are necessarily visible.
…
…
5126 FB PAR 26
5127 FBA PAR
REFRESH
Validates any changed adapter module configuration
parameter settings. After refreshing, the value reverts
automatically to
DONE
Refreshing done
0
REFRESH
Refreshing
1
5128 FILE CPI FW
REV
Displays the parameter table revision of the fieldbus adapter
module mapping file stored in the memory of the drive.
Format is xyz where:
• x = major revision number
• y = minor revision number
• x = correction letter.
0000…FFFF
hex
Parameter table revision
1 = 1
5129 FILE CONFIG
ID
Displays the drive type code of the fieldbus adapter module
mapping file stored in the memory of the drive.
0000…FFFF
hex
Drive type code of fieldbus adapter module mapping file
1 = 1
5130 FILE CONFIG
REV
Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format.
Example:
1 = revision 1.
0000…FFFF
hex
Mapping file revision
1 = 1
5131 FBA STATUS
Displays the status of the fieldbus adapter module
communication.
IDLE
Adapter is not configured.
0
EXECUT INIT
Adapter is initializing.
1
TIME OUT
A time-out has occurred in the communication between the
adapter and the drive.
2
CONFIG
ERROR
Adapter configuration error: The major or minor revision
code of the common program revision in the fieldbus
adapter module is not the revision required by the module
(see parameter
) or mapping file
upload has failed more than three times.
3
OFF-LINE
Adapter is off-line.
4
ON-LINE
Adapter is on-line.
5
RESET
Adapter is performing a hardware reset.
6
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...