Setting the Schedule
Press the
Schedule Measurement
soft key to display the following screen.
Executes initialization
Initializes the schedule settings to
factory default values.
Set the measurement interval (min)
(1 to 60).
Set the duration (days) (1 to 120).
Select a drive (Int. Memory, SD Card,
USB Memory1, USB Memory2).
Set the start time (OFF, ON).
Set the start date.
Set the start time.
Interval (min)
Set the interval to measure optical pulses.
The range is 1 to 60 minutes (in 1 minute steps).
Duration (days)
Set the duration to measure optical pulses.
The range is 1 to 120 days (in 1 day steps).
Setting Possible
The number of days is automatically calculated from the measurement interval and the size of
the memory in which measured data will be saved. The result is displayed here. Select the drive
according to the required duration. Note that even if a number greater than 120 is displayed, the
maximum duration (days) that you can set is 120.
Start Time Set
Measurement can be started from the specified time.
OFF: Measurement starts immediately.
ON: Measurement starts at the specified date and time.
Note
• When a schedule measurement is being performed, you cannot change the schedule.
• When a schedule measurement is being performed, you cannot perform marker analysis or event
analysis. When a schedule measurement is stopped, you can perform marker analysis or event analysis
on the measurement waveform data. But, you cannot save the analysis results.