4-20
IM AQ7280-01EN
Screen Display Item: List
1.
From the top menu, select
OTDR
.
2.
Press the
Event Analysis
soft key and then the
Display
soft key to select
List
. The following
screen appears.
Measurement conditions
For details on the measurement
conditions, see section 2.1.
Analysis values
List display
List Edit
See page 4-22.
Event Note Edit
See page 4-26.
Analysis values
• Total RL
The integrated value of the return losses of each event.
• Total Loss
Displayed in the following manner depending on the total loss calculation method.
Cumulate loss:
The integrated value of the splice losses at each event from the measurement
reference point (S) is displayed.
Loss between S and E:
The loss between the measurement reference point (S) and the end of fiber (E) is
displayed.
4.2 Analyzing Events