6.4 Others
6-31
6
Single-phase Power Supply Connection Example
6.4.8 DC Reactor for Harmonic Suppression
(1) Reactor Types
The SERVOPACK has the DC reactor connection terminals for power supply harmonic suppression. However,
SERVOPACKs with capacities of 6 kW or more do not have these terminals. The type of DC reactor to be con-
nected differs depending on the SERVOPACK capacity. Refer to the following table.
Note: Select a proper DC reactor for the input current to the SERVOPACK.
Refer to
2.6.2 Molded-case Circuit Breaker and Fuse Capacity
for input current to each
SERVOPACK. For the kind of reactor, refer to
5.8.13 DC Reactor for Harmonic Suppres-
sion
.
Single-phase
Magnetic contactor for
power supply ON and OFF
Voltage conversion
transformer
100 or 200 VAC
SERVOPACK
R
S
T
1KM
1KM
L1
L2
Applicable
SERVOPACK Model
SGDH-
DC Reactor
Model
Reactor Specifications
Inductance (mH)
Rated Current (A)
Single-phase
100 V
A3BE
−
−
−
A5BE
01BE
X5063
10.0
1.8
02BE
X5062
4.7
3.5
Single-phase
200 V
A3AE
−
−
−
A5AE
01AE
X5071
40.0
0.85
02AE
X5070
20.0
1.65
04AE
X5069
10.0
3.3
Single-phase
220 V
08AE-S
X5079
4.0
5.3
15AE-S
X5078
2.5
10.5
Three-phase
200 V
05AE
X5061
2.0
4.8
08AE
10AE
15AE
X5060
1.5
8.8
20AE
30AE
X5059
1.0
14.0
50AE
X5068
0.47
26.8
Three-phase
400 V
05DE
X5074
4.7
1.5
10DE
X5075
3.3
4.5
15DE
20DE
X5076
2.2
8.6
30DE
50DE
X5077
1.5
14.1
Содержание SGDH