4.4 SERVOPACK’s Power Supply Capacities and Power Losses
4-17
4
4.4 SERVOPACK’s Power Supply Capacities and Power Losses
The following table shows SERVOPACK’s power supply capacities and power losses at the rated output.
* 1. SERVOPACKs with a capacity of 30 to 400W do not have built-in regenerative resistors. If the
regenerative energy exceeds the specified value, connect an external regenerative resistor. Refer to
11.1.3 Calculating the Required Capacity of Regenerative Resistors.
* 2. Regenerative resistor power losses are allowable losses. Take the following action if this value is
exceeded.
• Remove the lead from the internal regenerative resistor in the SERVOPACK.
• Install an external regenerative resistor (optional).
Table 4.1 SERVOPACK Power Losses at Rated Output
Main Circuit Power
Supply
Maximum
Applicable
Servomotor
Capacity
kW
SERVOPACK
Model
SGDH-
Output
Current
(Effective
Value)
A
Main Circuit
Power Loss
W
Regenerative
Resistor
Power Loss
W
Control
Circuit
Power
Loss
W
Total
Power
Loss
W
Single-phase 100 V
0.03
A3BE
0.66
3.5
−
∗
1
13
16.5
0.05
A5BE
0.95
5.2
18.2
0.10
01BE
2.4
12
25
0.20
02BE
3.0
16.4
29.4
Single-phase 200 V
0.03
A3AE
0.44
3.1
−
∗
1
13
16.1
0.05
A5AE
0.64
4.6
17.6
0.10
01AE
0.91
6.7
19.7
0.20
02AE
2.1
13.3
26.3
0.40
04AE
2.8
20
33
Single-phase 220 V
0.75
08AE-S
4.4
47
12
∗
2
15
74
1.50
15AE-S
7.5
60
14
∗
2
89
Three-phase 200 V
0.45
05AE
3.8
27
12
∗
2
15
54
0.75
08AE
5.7
41
68
1.0
10AE
7.6
55
82
1.5
15AE
11.6
92
14
∗
2
121
2.0
20AE
18.5
120
28
∗
2
163
3.0
30AE
24.8
155
198
5.0
50AE
32.9
240
56
∗
2
311
6.0
60AE
46.9
290
−
∗
3
27
317
7.5
75AE
54.7
330
357
11
1AAE
58.6
360
30
390
15
1EAE
78.0
490
520
Three-phase 400 V
0.45
05DE
1.9
19
14
∗
2
15
48
1.0
10DE
3.5
35
64
1.5
15DE
5.4
53
82
2.0
20DE
8.4
83
28
∗
2
126
3.0
30DE
11.9
118
161
5.0
50DE
16.5
192
36
243
6.0
60DE
20.8
232
−
∗
3
247
7.5
75DE
25.4
264
279
11
1ADE
28.1
288
303
15
1EDE
37.2
392
407