11.3 List of Parameters
11-35
11
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn207
Position Control Function Switches
−
−
0000
After
restart
−
Pn208
Position Reference Movement Averaging
Time
0.00 to 64.00 ms
0.01 ms
0.00 ms
After
restart
8.6.4
Pn300
Speed Reference Input Gain
1.50 to 30.00 V
/ rated speed
0.01V
/ rated
speed
6.00 V
/ rated
speed
Immedi-
ately
8.5.1
8.7.4
9.4.3
Pn301
Speed 1
0 to 10000 min
-1
1 min
-1
100 min
-1
Immedi-
ately
8.8.1
Pn302
Speed 2
0 to 10000 min
-1
1 min
-1
200 min
-1
Immedi-
ately
8.8.1
Pn303
Speed 3
0 to 10000 min
-1
1 min
-1
300 min
-1
Immedi-
ately
8.8.1
Pn304
JOG Speed
0 to 10000 min
-1
1 min
-1
500 min
-1
Immedi-
ately
8.1.1
Pn305
Soft Start Acceleration Time
0 to 10000 ms
1 ms
0 ms
Immedi-
ately
8.5.4
Pn306
Soft Start Deceleration Time
0 to 10000 ms
1 ms
0 ms
Immedi-
ately
8.5.4
Pn307
Speed Reference Filter Time Constant
0.00 to 655.35 ms
0.01 ms
0.40 ms
Immedi-
ately
8.5.5
Pn308
Speed Feedback Filter Time Constant
0.00 to 655.35 ms
0.01 ms
0.00 ms
Immedi-
ately
9.4.7
Pn400
Torque Reference Input Gain
1.0 to10.0 V
/rated torque
0.1 V/rated
torque
3.0 V/
rated
torque
Immedi-
ately
8.7.1
8.9.3
8.9.4
9.4.2
Pn401
Torque Reference Filter Time Constant
0.00 to 655.35 ms
0.01 ms
1.00 ms
Immedi-
ately
9.4.10
Pn402
Forward Torque Limit
0 to 800%
1%
800%
Immedi-
ately
8.9.1
Pn403
Reverse Torque Limit
0 to 800%
1%
800%
Immedi-
ately
8.9.1
Pn404
Forward External Torque Limit
0 to 800%
1%
100%
Immedi-
ately
8.9.2
8.9.4
Pn405
Reverse External Torque Limit
0 to 800%
1%
100%
Immedi-
ately
8.9.2
8.9.4
0
1
Acceleration/deceleration
filter
Average movement filter
Reserved (Do not change)
Position Reference Filter Selection
(Refer to "8.6.4 Smoothing.")
Reserved (Do not change)
0
1
N/A
Uses V-REF as a speed feed-forward input.
Position Control Option
(Refer to "9.4.3 Speed Feed-forward.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Содержание SGDH