11 Appendix
11.3.2 List of Parameters
11-36
Pn406
Emergency Stop Torque
0 to 800%
1%
800%
Immedi-
ately
8.3.3
Pn407
Speed Limit during Torque Control
0 to 10000 min
-1
1 min
-1
10000
min
-1
Immedi-
ately
8.7.4
Pn408
Torque Function Switches
−
−
0000
Immedi-
ately
9.4.10
Pn409
Notch Filter Frequency
50 to 2000 Hz
1 Hz
2000 Hz
Immedi-
ately
9.4.10
Pn500
Positioning Completed Width
0 to 250 reference
units
1 reference
unit
7 refer-
ence units
Immedi-
ately
8.6.5
Pn501
Zero Clamp Level
0 to 10000 min
-1
1 min
-1
10 min
-1
Immedi-
ately
8.5.6
Pn502
Rotation Detection Level
1 to 10000 min
-1
1 min
-1
20 min
-1
Immedi-
ately
8.11.3
Pn503
Speed Coincidence Signal Output Width
0 to 100 min
-1
1 min
-1
10 min
-1
Immedi-
ately
8.5.8
Pn504
NEAR Signal Width
1 to 250 reference
units
1 reference
unit
7 refer-
ence units
Immedi-
ately
8.6.6
Pn505
Overflow Level
1 to 8388352
1 reference
unit
262144
reference
units
Immedi-
ately
9.3.3
Pn506
Brake Reference
-
Servo OFF Delay Time 1 to 50 (10 to 500 ms)
10 ms
10 ms
Immedi-
ately
8.3.4
Pn507
Brake Reference Output Speed Level
0 to 10000 min
-1
1 min
-1
100 min
-1
Immedi-
ately
8.3.4
Pn508
Timing for Brake Reference Output during
Motor Operation
10 to 100
(100 to 1000 ms)
10 ms
500 ms
Immedi-
ately
8.3.4
Pn509
Momentary Hold time
20 to 1000 ms
1 ms
20 ms
Immedi-
ately
8.3.6
Parameter
No.
Name
Setting Range
Unit
Factory
Setting
Setting
Validation
Reference
Section
0
1
N/A
Uses a notch filter for torque reference.
Notch Filter Selection
Reserved (Do not change)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Reserved (Do not change)
Reserved (Do not change)
Содержание SGDH
Страница 435: ...8 3 8...