8 Motion Commands
8-66
(b) Monitoring Parameters
(4) Timing Charts
(a) Normal End
(b) Error End
Parameter
Name
Monitor Contents
IL
02
Warning
Stores the most current warning.
IL
04
Alarm
Stores the most current alarm.
IW
08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 18 during PRM_WR command execution.
IB
090
Command Executing
Turns ON during PRM_WR command execution and turns OFF when execution
has been completed.
IB
091
Hold Completed
Always OFF for PRM_WR command.
IB
093
Command Error End
Turns ON if an error occurs during PRM_WR command execution. Turns OFF
when another command is executed.
IB
098
Command
Completed
Turns ON when PRM_WR command execution has been completed.
OW
08 = 18 (PRM-WR)
IW
08 = 18 (PRM-WR)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined
length of time
OW
08 = 18 (PRM-WR)
IW
08 = 18 (PRM-WR)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined
length of time