8 Motion Commands
8-84
(b) Monitoring Parameters
(4) Timing Charts
(a) Normal Execution
(b) Execution when an Alarm Occurs
Parameter
Name
Monitor Contents
IB
001
Servo ON
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
IL
02
Warning
Stores the most current warning.
IL
04
Alarm
Stores the most current alarm.
IW
08
Servo Command
Type Response
Indicates the motion command that is being executed.
The response code will be 25 during PHASE command execution.
IB
090
Command Executing
Always OFF for PHASE command.
IB
091
Hold Completed
Always OFF for PHASE command.
IB
093
Command Error End
Turns ON if an error occurs during PHASE command execution. The axis will
decelerate to a stop if it is moving. Turns OFF when another command is executed.
IB
098
Command
Completed
Always OFF for PHASE command.
OW
08 = 25 (PHASE)
IW
08 = 25 (PHASE)
IB
090 (BUSY)
Undefined length of time
IB
098 (COMPLETE)
IB
093 (FAIL)
IB
0C0 (DEN)
1 scan
Target position is changed automatically in every scan.
Undefined length of time
IB
0C1 (POSCOMP)
1 scan
Alarm
OW
08 = 25 (PHASE)
IW
08 = 25 (PHASE)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
IB
0C0 (DEN)