10.2 Startup the Absolute Position Detection Function
10-11
10
(3)
Σ
-
ΙΙΙ
Series
Use a digital operator to initialize the absolute encoder.
Step
Operation Key
Display Example
Description
1
Open the Utility Function Mode main menu and select
Fn008.
2
Press the
Key.
The display is switched to the execution display of
Fn008 (Absolute encoder multi-turn reset and encoder
alarm reset).
Note: If the display is not switched and “NO_OP” is dis-
played in the status display, the Write Prohibited
Setting (Fn010 = 0001) is set. Check the status
and reset.
3
Keep pressing the
Key until “PGCL1” is changed
to “PGCL5.”
4
Press the
Key. “BB” in the status display changes
to “Done.”
5
Press the
Key. The display returns to the Utility
Function Mode main menu.
6
The completes initializing the absolute encoder.
Turn the power supply OFF and then back ON to enable the setting.
B B
−
F U N C T I O N
−
F n 0 0 7
F n 0 0 8
F n 0 0 9
F n 0 0 A
B B
M u l t i t u r n C l e a r
P G C L 1
B B
M u l t i t u r n C l e a r
P G C L 1
D o n e
M u l t i t u r n C l e a r
P G C L 5
B B
−
F U N C T I O N
−
F n 0 0 7
F n 0 0 8
F n 0 0 9
F n 0 0 A