8 Motion Commands
8-60
(3) Related Parameters
(a) Setting Parameters
(b) Monitoring Parameters
(4) Timing Charts
(a) Normal End
(b) Error End
Parameter
Name
Setting
OW
08
Motion Command
The position loop gain is changed when this parameter is set to 15.
OB
090
Command Pause
This parameter is ignored for KPS command.
OB
091
Command Abort
This parameter is ignored for KPS command.
OW
2E
Position Loop Gain
Set the gain for the SERVOPACK position control loop.
Parameter
Name
Monitor Contents
IL
02
Warning
Stores the most current warning.
IL
04
Alarm
Stores the most current alarm.
IW
08
Servo Command Type
Response
Indicates the motion command that is being executed.
The response code is 15 during KPS command execution.
IB
090
Command Executing
Turns ON during KPS command execution and turns OFF when execution has
been completed.
IB
091
Hold Completed
Always OFF for KPS command.
IB
093
Command Error End
Turns ON if an error occurs during KPS command execution. Turns OFF when
another command is executed.
IB
098
Command Completed
Turns ON when KPS command execution has been completed.
OW
08 = 15 (KPS)
IW
08 = 15 (KPS)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined
length of time
OW
08 = 15 (KPS)
IW
08 = 15 (KPS)
IB
090 (BUSY)
IB
098 (COMPLETE)
IB
093 (FAIL)
Undefined
length of time