7 Motion Parameters
7.2.3 Motion Monitoring Parameter Details
7-44
(18) Absolute Infinite Length Axis Position Control Information
(19) Transparent Command Mode
IL
5E
Absolute Position at Power OFF (Low Value)
Range
Unit
−
2
31
to 2
31
−
1
pulse
Stores information used for infinite length axis position control when an absolute encoder is used.
These parameters store the encoder position in 4 words.
IL
60
Absolute Position at Power OFF (High Value)
Range
Unit
−
2
31
to 2
31
−
1
pulse
Same as for IL
5E.
IL
62
Modularized Position at Power OFF (Low Value)
Range
Unit
−
2
31
to 2
31
−
1
pulse
Stores information used for infinite length axis position control when an absolute encoder is used.
These parameters store the axis position managed by the MP2100/MP2100M in pulses in 4 words.
IL
64
Modularized Position at Power OFF (High Value)
Range
Unit
−
2
31
to 2
31
−
1
pulse
Same as for IL
62.
IW
70 to IW
7E
Command Buffer for Transparent Command Mode
Range
Unit
−
2
31
to 2
31
−
1
−
This area is used for response data when MECHATROLINK Servo commands are specified directly.
• MECHATROLINK-I and MECHATROLINK-II, 17-byte Mode: Data area = IW
70 to IW
77
• MECHATROLINK-II, 32-byte Mode: Data area = IW
70 to IW
7E