596
YASKAWA
TOEPYAIGA8002B GA800 Drive Programming
Auto-Tuning Type
Mode
Multifunctional input
Multifunctional output
EZ Tuning
Stationary
Motor Parameter Setting
Disabled
Disabled
Line-to-Line Resistance
Disabled
Keeps the status at the start of
Auto-Tuning.
ASR and Inertia Tuning
Rotational
Inertia Tuning
Disabled
Functions the same as during usual
operation.
ASR (Speed Regulator)
Disabled
Functions the same as during usual
operation.
Deceleration Rate Tuning
Disabled
Functions the same as during usual
operation.
KEB Tuning
Disabled
Functions the same as during usual
operation.
*1
A
terminal
to
which
H2-xx
=
E
[MFDO
Function
Select
=
Fault]
is
assigned
functions
the
same
as
during
usual
operation.
WARNING!
Crush
Hazard.
Wire
a
sequence
that
will
not
let
a
multi-function
output
terminal
open
the
holding
brake
during
Stationary
Auto-Tuning.
If
the
holding
brake
is
open
during
Stationary
Auto-Tuning,
it
can
cause
serious
injury
or
death.
WARNING!
Before
you
do
Rotational
Auto-Tuning,
disconnect
the
load
from
the
motor.
The
load
can
move
suddenly
and
cause
serious
injury
or
death.
WARNING!
Electrical
Shock
Hazard.
During
Auto-Tuning,
the
motor
will
receive
high
voltage
when
the
motor
is
stopped.
Do
not
touch
the
motor
until
Auto-Tuning
is
complete.
If
you
touch
a
motor
that
is
energized,
it
can
cause
serious
injury
or
death.
■
Precautions before Rotational Auto-Tuning
WARNING!
Electrical Shock Hazard. During Auto-Tuning, the motor will receive high voltage when the motor is stopped. Do not
touch the motor until Auto-Tuning is complete. If you touch a motor that is energized, it can cause serious injury or death.
•
Uncouple the drive from the motor before Rotational Auto-Tuning to prevent drive malfunction. If you do
Rotational Auto-Tuning with the motor connected to a load that is more than 30% of the motor duty rating, the
drive will not correctly calculate the motor parameters and the motor can operate incorrectly.
•
When the load is 30% or less of the motor duty rating, you can do Auto-Tuning with the motor connected to a load.
•
Make sure that the motor magnetic brake is released.
•
Make sure that external force from the machine will not cause the motor to rotate.
■
Precautions before Stationary Auto-Tuning
•
Make sure that the motor magnetic brake is not open.
•
Make sure that external force from the machine will not cause the motor to rotate.
WARNING!
Electrical Shock Hazard. During Auto-Tuning, the motor will receive high voltage when the motor is stopped. Do not
touch the motor until Auto-Tuning is complete. If you touch a motor that is energized, it can cause serious injury or death.
Automatically Set E2-02 [Motor Rated Slip] and E2-03 [Motor No-Load Current]
If
T1-12 = 1 [Test Mode Selection = Yes]
when selecting Stationary Auto-Tuning, the drive will automatically set
motor parameters
E2-02 [Motor Rated Slip]
and
E2-03 [Motor No-Load Current]
after Auto-Tuning is complete
when you use the motor for the first time in Drive Mode.
After Stationary Auto-Tuning is complete, use this procedures to do the operation in test mode:
1. Check the
E2-02
and
E2-03
values on the
“
Modified Parameters/Fault Log
”
screen or the
“
Parameters
”
screen.
2. Operate the motor in Drive Mode with these conditions:
•
Make sure that you connect all wiring between the drive and motor
•
Make sure that a mechanical brake on the motor shaft is not locked
•
The maximum motor load must be 30% of the rated load.
•
Keep a constant speed of 30% of
E1-06 [Base Frequency]
(default value = maximum frequency) or more for 1
second or longer.
3. After the motor stops, check the
E2-02
and
E2-03
values on the
“
Modified Parameters/Fault Log
”
screen or the
“
Parameters
”
screen again.
4. Make sure that the input data is correct.
When the settings in
E2-02
and
E2-03
are different than in step 1, the drive set the values automatically.